Data Centre &
Server Room Cabling.

Cat6A, OM4/OM5/OS2 fiber, MPO trunks, patch panels, containment and rack builds. Certified on every run, documented port by port, and installed in live rooms without downtime.

Data centre cabinet with structured Cat6A cabling and patch panels
Cabinet build — Cat6A, fiber, dressed and labelled
Copper
Cat6A / TIA-568
Fiber
OM4 · OM5 · OS2
Testing
Fluke DSX + OTDR
Survey
Booked in 48 hours
01
Overview

What data centre cabling actually involves

Data centre cabling is the structured copper and fiber inside a server room or data hall: Cat6A horizontal runs to each rack, fiber backbone between rows and to the MDF, patch panels, MPO trunks, overhead containment, and the labelling and test records that make it traceable. It is built to a tighter density and documentation standard than office cabling.

The difference is not the cable, it is the tolerance. An office can absorb a messy closet. A data hall cannot: cable congestion blocks airflow, undocumented ports cost hours during an incident, and a full tray means the next cabinet gets surface-run cable along the wrong path. We build rooms so the fifth expansion is as clean as the first.

02
Scope

What we install

U1

Cat6A structured cabling

Horizontal runs cabinet to patch panel, shielded or UTP, terminated to TIA-568 permanent link limits. 10GbE and PoE++ rated throughout.

10GbE · PoE++ 90W
U2

Fiber backbone

OM4 and OM5 multimode row to row and row to MDF. OS2 single-mode for inter-building and long links. Fusion spliced on site.

OM4 · OM5 · OS2
U3

MPO / MTP trunk systems

Pre-terminated 12 and 24-fibre trunks with cassettes. Fast deployment, consistent loss budget, no field splicing in the cabinet.

12F · 24F · cassettes
U4

Patch panels & rack builds

Copper and fiber panels, cabinets and open racks, vertical and horizontal managers, blanking and airflow discipline.

1U / 2U · angled / flat
U5

Overhead containment

Ladder rack, basket tray and waterfall drops sized to 40 percent fill. Copper and fiber on separate paths per TIA-942.

Ladder · basket · 40% fill
U6

MDF & IDF build-outs

Main and intermediate frames for multi-floor and campus sites. Sequenced panels, fiber enclosures, full port documentation.

MDF · IDF · riser
U7

Certification & documentation

Fluke DSX on every copper run, OTDR on every strand, TIA-606 labelling, patch schedule and as-built drawings.

DSX · OTDR · TIA-606
U8

Migrations & decommissioning

Cabinet moves, controlled cutovers with written rollback, abandoned cable removal to code, and re-certification after change.

Cutover · rollback · abatement
03
Media selection

Which media for which link

Cat6A for horizontal runs inside a cabinet row. OM4 for row-to-row and row-to-MDF backbone. OM5 where 400G headroom is wanted. OS2 between buildings or past multimode distance. MPO trunks wherever cabinet density makes field termination impractical.

MediaLinkRateReach
Cat6ACabinet to patch panel, ToR uplink10GbE / PoE++100 m
OM4Row to row, row to MDF100GbE100 m
OM5High-density backbone, SWDM4400GbE150 m
OS2Building to building, campus, long haul100GbE+10 km+
MPO 12F/24FCabinet trunks, cassette to cassette40G / 100G / 400GPre-terminated

Related: fiber optic cabling · splicing & termination · Cat6A cabling · cable tray

04
Live environments

Working in a running room

Yes, we cable live data centres without downtime. We pull to spare pathway, stage cabinet by cabinet, and cut over inside agreed maintenance windows — never without a written rollback plan.

  • Pathway first. New cable lands in spare tray before anything is touched at the cabinet.
  • Staged by cabinet. One row at a time, so exposure is bounded and reversible.
  • Written change windows. Access, escort and cutover times agreed before mobilisation.
  • Airflow protected. No cable across a cold aisle, no blocked perforated tile, blanking reinstated.
  • Rollback documented. Every cutover has a defined revert path and a stop point.
Fiber optic trunk cabling routed into a data centre patch panel
Fiber trunk into cassette — staged cutover
05
Get a quote

Free room survey, fixed written price

Tell us the room and roughly what you need. We survey in person, then issue an itemised fixed quote. We do not price data centre work over the phone.

  • Survey booked within 48 hours
  • Fluke DSX and OTDR results at handover
  • TIA-606 labelling and patch schedule
  • Live-room work with written rollback

Used only to answer this enquiry. Privacy policy.

06
FAQ

Common questions

Data centre cabling is the structured copper and fiber infrastructure inside a server room or data hall: Cat6A horizontal runs to each rack, fiber backbone between rows and to the MDF, patch panels, MPO trunks, overhead containment and the labelling and test records that make it all traceable. It is built to a tighter density and documentation standard than office cabling.
Yes. Most of our data centre work happens in live rooms. We pull to spare pathway, stage cabinet by cabinet, cut over during agreed maintenance windows, and never work a live cutover without a written rollback plan. Access and change windows are agreed before anyone is on site.
OM4 multimode handles 100GbE to 100m and covers most row-to-row and row-to-MDF links. OM5 extends that to 400GbE via SWDM4 for higher-density builds. OS2 single-mode is used between buildings and for any run past multimode distance limits. MPO and MTP pre-terminated trunks are standard for high-density cabinets.
Every copper run is certified with a Fluke DSX CableAnalyzer against TIA-568 permanent link or channel limits. Every fiber strand is OTDR tested with traces supplied, plus insertion loss testing on each link. You receive the full test set, TIA-606 labelling and a port-by-port patch schedule.
Yes. We supply and install cabinets and open racks, vertical and horizontal managers, overhead ladder rack and basket tray, copper and fiber patch panels, and fiber enclosures. Pathway is sized to 40 percent fill so there is capacity left for the next expansion.
It depends on port count, fiber strand count, cabinet count, containment length, and whether the room is live. We survey the room first, then issue an itemised fixed-price quote. We do not price data centre work over the phone.